<strong id="jeslp"></strong>
    <strong id="jeslp"></strong>
    1. <mark id="jeslp"></mark>
    2. <ruby id="jeslp"><table id="jeslp"></table></ruby>
    3. <ruby id="jeslp"></ruby>
      <acronym id="jeslp"></acronym><strong id="jeslp"></strong>
      <strong id="jeslp"></strong>
      在線(xiàn)客服
      熱線(xiàn)電話(huà)

      微信公眾賬號
      Hello! Welcome to Shenzhen Tergy Technology Co., Ltd.
      全國服務(wù)熱線(xiàn)
      They are in search:Fuse | ESD protector | TVS diode | varistor | gravitron | MLCV | self recovery fuse
      Support
      Search
         Product Category Search
      Latest applications
      Contact Us
       
      Company Name: Shenzhen Tage Technology Co., Ltd.
      Phone: 86-755-88365418,88365225,88363209
      Fax: 86-755-88361758 Holiday Service Phone: 18128869501 E-mail: evan@tergy.com
      Address: Shenzhen Baoan District city streets of entrepreneurship garden Amoy king business building

      Support

      You are here:Home >> Support >> Support
      Self recovery fuse selection method
      Publish:Shenzhen Tergy Technology Co., Ltd.  Time:2016-08-01
      1, determine the parameters of the circuit:
      A maximum operating ambient temperature B standard operating current C maximum working voltage (Umax) d maximum fault current (Imax)
      2, the principle of self recovery fuse
      Self recovery fuse is made by special process of high tech polymer resin and nano conductive grains.
      With the resin based conductive path forming a chain link, fuse the normal work; when the circuit short-circuit or overload, large current flows through the fuse set temperature, when the temperature reaches Curie, its density decreases rapidly, phase transition increases, a conductive link inside the avalanche state change or break, a fuse step - moved to the high impedance state current is quickly pinch off, thus to circuit fast, accurate limit and protect the small current of the fuse has been in a state of protection, when power failure and fault exclusion, the set temperature decreased, the density of States increases, phase recovery, nano crystal reduction into a chain of conductive path, since the recovery fuse returned to normal, without manual change.
      自恢復保險絲選型方法
      3, the maximum electrical rating of the selected components and the maximum operating voltage of the circuit and the fault current for comparison
      Use the electrical characteristics table to verify the maximum operating voltage and fault current of the device you selected in the second step. Maximum operating voltage and maximum fault current of the device. Make sure that Umax and Imax are greater than or equal to the maximum operating voltage and maximum fault current of the circuit.
      4, according to the maximum operating temperature of the circuit and the circuit, the control self recovery fuse temperature reduction rate to choose the appropriate product specifications to maintain the current
      5, verify the working temperature of the environment
      Ensure that the minimum and maximum ambient temperature of the application is within the operating temperature range of the self recovery fuse element. Most of the operating temperature ranges from -40 to 85.
      6 control specifications provided by the data, confirm the specifications of the thermistor size to meet the requirements.
      Previous:  2020/07/27
      Next:Principle and application of ESD protector  2016/08/01
      Products
      亚洲精品防屏蔽_成人h动漫精品一区二区无码_国产成人亚洲欧美二区综合_无码专区久久综合久中文字幕
      <strong id="jeslp"></strong>
      <strong id="jeslp"></strong>
      1. <mark id="jeslp"></mark>
      2. <ruby id="jeslp"><table id="jeslp"></table></ruby>
      3. <ruby id="jeslp"></ruby>
        <acronym id="jeslp"></acronym><strong id="jeslp"></strong>
        <strong id="jeslp"></strong>